WERA HF Radar Software - eXtended Header Mode Information

The following table describes the values to be set by WeraDesk to control the measurement cycles:

  start_acq stopp_acq SNGL CONT TEST FM_MODE header.
typenum
Continuous Acquisition 1 0 0 1 0 FMSOCO 8
Stop Continuous Acquisition 0 1 0 1 0 FMSOCO 8
Single Acquisition 1 0 1 0 0 FMSOCO 8
Calibration 1 0 1 0 0 FMCALI 11
Cont. Calibration 1 0 0 1 0 FMCALI 11
Stop Cont. Calibration 0 1 0 1 0 FMCALI 11
Full Calibration 0 1 1 1 0 FMCALI 11
FM raw Acquisition 1 0 1 0 0 FMCASW 9
Test Acquisition 1 0 1 0 1 FMSOCO 8
Test Calibration 1 0 1 0 1 FMCALI 11
Test Stop 0 1 1 0 1 FMSOCO 8
Used by mkcron X X X X X    
Used by stm X X X X X X X

'FM_MODE' is internally represented by 'header.typenum'; it is the same information in a different form.